IVCM1012 12 V, 1 kW, 1000 W, single-phase, low voltage solar inverter

This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterrupted power support with portable size. Its full LCD display offers user-configurable and easily accessible button operation, such as battery charging current, solar/AC charger priority and acceptable input voltage based on different applications.
Features

-Pure sine wave inverter
-Integrated MPPT solar charge controller
-Configurable input voltage range for home appliances and personal computers through LCD settings
-Configurable battery charging current according to the applications through LCD settings
-Configurable solar/AC charger priority through LCD configuration
-Compatible with mains voltage or generator power
-Automatic restart while the AC is recovering
Overload/overtemperature/short-circuit protection -Cold start function
-Depending on the model, Turbo mode can be enabled in APL mode to use up to three times the maximum rated load.

Share:

 

Line mode specifications
Model IVCM1012 IVCM2024 IVCM3024
 Rated output power 1000 VA/1000 W 2000 VA/2000 W 3000 VA/3000 W
 Instantaneous power output 2000 VA 4000 VA 6000 VA
Rated DC input voltage 12 V 24 V 24 V
Input voltage waveform Sinusoidal (utility or generator)
Rated input voltage 230 V AC
Low line voltage disconnection 170 V AC ± 7 V (UPS); 90 V AC ± 7 V (appliances)
Low loss voltage reconnection 180 V AC ± 7 V (UPS); 100 V AC ± 7 V (household appliances)
High line voltage disconnection 280 V AC ± 7 V
High line voltage reconnection 270 V AC ± 7 V
Maximum AC input voltage 300 V AC
Nominal input frequency 50 Hz/60 Hz (automatic detection)
Low frequency line disconnection 40 ± 1 Hz
Low frequency line reconnection 42 ± 1 Hz
High frequency line disconnection 65 ± 1 Hz
High frequency line reconnection 63 ± 1 Hz
Output voltage waveform Same as input waveform
Output short-circuit protection Line mode: Circuit breaker Battery mode: Electronic circuitry
Efficiency (Line mode) >95 % (nominal load R, fully charged battery)
Transfer time (single unit) 10 ms typical (UPS); 20 ms typical (appliances)
Maximum shunt overload current 10A 15A 30A
Maximum current of inverter/rectifier 5 A/1000 W 10 A/2000 W 15 A/3000 W
Utility charging mode specifications
Rated input voltage 230 V AC
Input voltage range 90-280 V AC
Rated output voltage Depends on battery type
Maximum load current 20A 30A
Load current regulation 10-20 A (Setting 10 A) 20-30 A (adjustable 10 A)
Overload protection Yes
Solar charging and grid charging
Maximum photovoltaic open circuit voltage 95 V 145 V
Operating voltage range 15-80 V 30-125 V
Maximum input power 900 W 1800 W
Maximum solar charging current 60A
Maximum load current (photovoltaic + network) 80A 90A
Maximum input current 35A

 

Product highlights